How to integrate with OmniMD
This page lists what OmniMD publishes for integrations, from ONC's Certified Health IT Product List (CHPL) and ONC Lantern, as of 2026-11-11. Website: https://omnimd.com.
Certified products
| Product | Latest version | Status | Certified | CHPL listing |
|---|---|---|---|---|
| OmniMD | 20 | Active | 2023-10-24 | 15.05.05.1717.OM20.02.02.1.231024 |
Published API documentation
- Standardized API for Patient and Population Services (170.315 (g)(10)): https://fhirregistration.omnimd.com/docs
- Application Access - Patient Selection (170.315 (g)(7)): https://www.omnimd.com/open-api/
- Application Access - All Data Request (170.315 (g)(9)): https://www.omnimd.com/open-api/
FHIR endpoints
Service base URL list, which gives the FHIR endpoint for each customer: https://hapi.omnimd.com/fhir/servicebaseurls.
ONC Lantern tracks 1 FHIR endpoints for OmniMD. Reported FHIR versions: 4.0.1 (1).
How to integrate
- Read the (g)(10) documentation above. ONC criterion 170.315(g)(10) requires a standardized FHIR API for patient and population services.
- Register your application with the vendor, as its documentation describes.
- Authorize with SMART App Launch, or with SMART Backend Services for system-to-system access.
- Find the practice's FHIR base URL in the service base URL list.
- Plan for the gaps. (g)(10) certifies read access to USCDI data. Scheduling, charges, claims and write-back need vendor-specific APIs or another route.